DIAGNOSTICS OK WL SENSORS TEST WL SIRENS TEST OK OK DIAG. TESTING S1 CPU (Perform walk test) OK Example BATHROOM WAIT of test Z19 STRONG result S1 CPU=STRONG display NEXT DIAG.
TESTING S2 CPU OK OK FRONT DOOR Example of test PLEASE WAIT. (alternating for 5 sec.) result S2 CPU=STRONG Z1 POOR display Note OK STRONG/GOOD/POOR/ LIVING ROOM Example “NOT OK” (with siren No., of test S1 or S2 before) is (alternating for 5 sec.) result displayed according to the Z2 OK display wireless siren signal strength). OK S1=siren 1. S2 = siren 2.
Resetting Powermax Installer Code. Honeywell’s LYNX Touch is a lifestyle enhancing touchscreen security system that puts information and control at your. Download Portable Corel Draw. Honeywell L5100: Reset the Master Code Alarm. How to reset the installer code. How to reset or change the master code on the Honeywell L5100.
(Each time the OK button is pressed, CPU = Control Panel Unit the next text result is displayed) = 2 way comm. Stanton Warriors Remixes Torrent. Figure 4.9 - Diagnostic Test Flow Chart 4.10 USER FUNCTIONS This mode provides you with a gateway to the user functions through the regular user programming menu. You may: • Program the 4 (private) telephone numbers • Program user codes • Enroll keyfobs • Select the voice option • Set the auto arm option • Set arming time • Set the squawk option • Set the system time and time format • Set the date and date format • Set the time scheduler Refer to the User Guide for detailed procedures.
If after having programmed the user codes the system does not recognize your installer code, this indicates you must have programmed a user code that is identical with your installer code. Fl 12.5 Regkey. If so, access the user menu and change the code that is identical with your installer code. This will re-validate your installer code. 4.11 RETRIEVING FACTORY DEFAULTS If you want to reset the PowerMax+ parameters to the factory default parameters, you should enter the installer menu and perform the 'FACTORY DEFLT' function, as described in the right side illustration. To get the relevant parameters defaults, contact the PowerMax+ dealer.
Note: For PowerMax+ with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master installer code enables to perform factory default function. Entering to/exit from the FACTORY DEFLT menu is shown in figure 4.1a This is a brief display after which all the factory defaults are retrieved. FACTORY DEFLT OK to restore OK ENTER CODE: [installer code] PLEASE WAIT. 4.12 SERIAL NUMBER The menu '12. SERIAL NUMBER' enables reading the system serial number for support purposes only.
4.13 CALLING UPLOAD/DOWNLOAD SERVER This option allows the installer to initate a call to the upload/download server. The server uploads the PowerMax+ configuration to its data base and can unload predefined parameters to the PowerMax+. 22 DE5467IP READY 00:00 NEXT NORMAL MODE NEXT USER SETTINGS NEXT INSTALLER MODE OK ENTER CODE [installer code] 1. NEW INSTL CODE NEXT 2. ENROLLING NEXT 3. DEFINE ZONES NEXT 4. DEFINE PANEL NEXT 5.
DEFINE COMM NEXT 6. DEFINE GSM NEXT 7. DEFINE OUTPUTS NEXT 8. RECORD SPEECH NEXT 9. DIAGNOSTICS NEXT 10. USER SETTINGS NEXT 11.
FACTORY DEFLT NEXT 12. SERIAL NUMBER NEXT 13. START UL/DL NEXT TO EXIT OK Displayed during dialing process Displayed during download process Displayed for half a minute approx. Accomapnied by sad (failure) melody If UL/DL server tel. # is already defined (see par. 4.5.34) COMMUNICATING Dialing OK DOWNLOADING Download OK DOWNLOAD OK If UL/DL server tel. # was not defined before (see par.